UKO-11: tapered galvanised residential-area lighting pole, 11 m
A tapered galvanised residential-area lighting pole 11 m high for streets, courtyards, walks, boulevards and pedestrian zones.
Technical parameters of the UKO-11 pole
| Parameter | Value |
|---|---|
| Pole height, H | 11 m |
| Top diameter, ∅a | 60 mm |
| Bottom diameter, ∅b | 192 mm |
| Wall thickness | 4 mm |
| Base plate size | 300×300 mm |
| Centre distance between the base plate holes, B | 220×220 mm |
| Anchor bolts | 4 bolts M24 |
| Foundation anchor cage | FPO-1500-2 |
| Hatch: height W × width v | 500 × 90 mm |
| Distance from the hatch to the pole base, Wp | 600 mm |
| Pole mass | 150 kg |
| Material | steel S245, S255 (DBN V.2.6-198:2014) |
| Corrosion protection | hot-dip galvanising to DSTU EN ISO 1461:2024 |
Price of the UKO-11
Price of UKO poles: from UAH 5,100 to 27,500 each including VAT (as of September 2026), a range for the whole height series. The UKO-11 price within it depends on height and fit-out; the exact price comes from a calculation — tell us the quantity and the delivery place.
The price includes the galvanised shaft and the inspection hatch. The FPO-1500-2 anchor cage, brackets, crossarms, delivery and installation are priced separately.
Delivery terms for the UKO-11
| Term | Our terms |
|---|---|
| Availability | All ranges are in stock. Made to order: 3–4 weeks |
| Minimum order | From 1 pc; from 50 pcs, terms are agreed individually |
| Delivery and pickup | By carrier across Ukraine; pickup from the warehouse in Bila Tserkva |
| Payment | Cashless payment incl. VAT, 70% prepayment |
| Warranty | 2 years |
| Documents | Quality certificate |
Where UKO-11 is used
The UKO-11 lighting pole is used for luminaires, floodlights and video surveillance equipment. It suits trench and overhead cable supply and is also used in private housing estates and other sites.
The UKO-11 is at the top of the street range: wide roadways where a long spacing is needed. The strip is about 16.5 m with staggered spacing and up to 22 m with opposite spacing.
The hatch at the bottom of the pole is standard. On request we make the pole without a hatch, in a hinged version with a hinged anchor cage, and paint it any colour.
Permitted luminaire area on the UKO-11
Permitted total luminaire area on the UKO-11 (Caer = 1, terrain type III) at different wind pressures; Q and M are the shear force and bending moment at the pole base. Check your own luminaires in the pole selection calculator by area and mass.
| Hs, m | S, m | Equipment mass, kg | Q, kN | M, kN·m | 400 Pa, m² | 450 Pa, m² | 500 Pa, m² | 550 Pa, m² | 600 Pa, m² |
|---|---|---|---|---|---|---|---|---|---|
| – | – | 50 (on the axis) | 1,65 | 11,77 | 1,182 | 0,989 | 0,836 | 0,712 | 0,610 |
| 12 | 1,5 | 15 (on a 1-arm bracket) | 1,65 | 11,77 | 0,984 | 0,802 | 0,659 | 0,543 | 0,446 |
| 12 | 2х1,5 | 2х15 (on a 2-arm bracket) | 1,65 | 11,77 | 0,410 | 0,324 | 0,255 | 0,200 | 0,154 |
Installation and foundation of the UKO-11 pole
The UKO-11 pole stands on a foundation anchor cage: it is placed in the formwork and concreted with the foundation in advance, and the pole flange is bolted to the anchor bolts. More in Foundation anchor cages FPO, FPM, FKM and Lighting pole foundations.
Matching parts for the UKO-11
- Anchor cage: FPO-1500-2 — 1500 mm high, anchor bolts M24, 4 pcs.
- Brackets KO1 and KO2: KO1(2)-1-1-1.5 (one arm) and KO1(2)-2-1-1.5 (two arms) — the load table is calculated for them.
Material and corrosion protection
For steel 4 mm thick, ISO 1461 requires a mean zinc coating thickness of at least 70 µm (local at least 55 µm). How it is checked: Zinc coating thickness.
The UKO-11 pole in numbers
The pole mass is 150 kg, about 13.6 kg per metre of height. The diameter decreases from 192 mm at the bottom to 60 mm at the top, by about 12 mm per metre.
UKO-11: luminaire load and spacing
At 11 m the conical UKO-11 has more margin than the multi-sided UMO-11. On top at 400 Pa it allows 1.182 m² against 1.114 m². On a single-arm bracket it is 0.984 against 0.916 m², on a two-arm bracket 0.41 against 0.376 m². At 500 Pa UKO-11 allows 0.836, 0.659 and 0.255 m² respectively. A 0.35 m², 14 kg luminaire on a 1.5 m outreach passes at both pressures. A pair of 0.2 m² units on two arms fits only at 400 Pa. The pole stands on an FPO-1500-2 anchor cage. Guide spacing is 33–44 m, finalised by a lighting calculation. Mass is limited to 15 kg per arm and 50 kg on top. Your own luminaire combination can be checked in the calculator for selecting a pole by luminaire area and mass.
Get a quote for your requirements
Send us your requirements — we will calculate the price and lead time.