Home / Products / Overhead line fittings and crossarms (0.4-10 kV) / Catalogue of Fittings for 0.4–10 kV Overhead Lines: TM Cross-arms, TS Extensions, OG Pole Heads and Plates, Bolts and Clamps
Overhead line fittings and crossarms (0.4-10 kV)
Catalogue of Fittings for 0.4–10 kV Overhead Lines: TM Cross-arms, TS Extensions, OG Pole Heads and Plates, Bolts and Clamps
Codes of fittings for 0.4–10 kV overhead line poles: TM cross-arms, TS extensions, OG and OT pole heads and plates, bolts and clamps. Every item comes with its drawing number and mass. We make the parts with hot-dip galvanising.

Contents
How to use the catalogue
The tables below list steel fittings for 0.4–10 kV overhead line poles that we make to the standard album 3.407.1-143 (issue 8, “Steel structures of poles”). Each row gives the designation, the drawing number and the mass. The “Also written” column helps if your specification spells a code differently: the same part turns up as “TM-3”, “TM3” and “TM 3”. Designations are transliterated into Latin letters from the original Cyrillic codes (T = Т, M = М, S = С, O = О, G = Г, B = Б, Kh = Х).
- the drawing number lets you check the composition and dimensions of a part against the album;
- the mass is taken from the drawing, before galvanising: hot-dip galvanising adds the mass of the coating;
- which parts a given pole needs is decided by the line design, either a standard solution or the customer’s drawing;
- if a part is not in the tables, we will make it to your drawing or sketch (KM or KMD).
TM cross-arms
TM steel cross-arms hold the wires and insulators on pole shafts. The table lists the items we make, with drawing numbers and mass.
| Designation | Also written | Drawing | Mass, kg |
|---|---|---|---|
| TM-1, TM-24 | TM1, TM 1, TM24, TM 24 | 3.407.1-143.8.1 | 17.2; TM-24 — mass 18.6 |
| TM-2 | TM2, TM 2 | 3.407.1-143.8.2 | 10.9 |
| TM-3 | TM3, TM 3 | 3.407.1-143.8.3 | 21.0 |
| TM-4 | TM4, TM 4 | 3.407.1-143.8.4 | 14.2 |
| TM-5 | TM5, TM 5 | 3.407.1-143.8.5 | 17.3 |
| TM-6 | TM6, TM 6 | 3.407.1-143.8.6 | 23.0 |
| TM-7 | TM7, TM 7 | 3.407.1-143.8.7 | 25.8 |
| TM-8 | TM8, TM 8 | 3.407.1-143.8.8 | 26.0 |
| TM-9 | TM9, TM 9 | 3.407.1-143.8.9 | 10.1 |
| TM-10 | TM10, TM 10 | 3.407.1-143.8.10 | 11.5 |
| TM-11 | TM11, TM 11 | 3.407.1-143.8.11 | 25.0 |
| TM-12 | TM12, TM 12 | 3.407.1-143.8.12 | 33.4 |
| TM-13 | TM13, TM 13 | 3.407.1-143.8.13 | 32.6 |
| TM-14 | TM14, TM 14 | 3.407.1-143.8.14 | 26.3 |
| TM-15 | TM15, TM 15 | 3.407.1-143.8.15 | 18.5 |
| TM-16 | TM16, TM 16 | 3.407.1-143.8.16 | 18.3 |
| TM-17 | TM17, TM 17 | 3.407.1-143.8.17 | 23.6 |
| TM-18 | TM18, TM 18 | 3.407.1-143.8.18 | 16.8 |
| TM-19 | TM19, TM 19 | 3.407.1-143.8.12 | 38.0 |
| TM-20 | TM20, TM 20 | 3.407.1-143.8.19 | 45.0 |
| TM-21 | TM21, TM 21 | 3.407.1-143.8.20 | 24.5 |
| TM-22 | TM22, TM 22 | 3.407.1-143.8.21 | 40.8 |
| TM-23 | TM23, TM 23 | 3.407.1-143.8.22 | 34.9 |
| TM-30 | TM30, TM 30 | 3.407.1-143.8.70 | 38.1 |
| TM-31 | TM31, TM 31 | 3.407.1-143.8.22 | 30.2 |
TS extensions
TS extensions lengthen the upper part of a pole.
| Designation | Also written | Drawing | Mass, kg |
|---|---|---|---|
| TS-1 | TS1 | 3.407.1-143.8.23 | 76.5 |
| TS-2 | TS2 | 3.407.1-143.8.24 | 22.8 |
| TS-4 | TS4 | 3.407.1-143.8.25 | 30.3 |
| TS-6 | TS6, TS 6 | 3.407.1-143.8.71 | 35.7 |
OG pole heads
OG pole heads are fitted to the upper end of a pole shaft.
| Designation | Also written | Drawing | Mass, kg |
|---|---|---|---|
| OG-1 | OG1, OG 1 | 3.407.1-143.8.25 | 7.8 |
| OG-7 | OG7, OG 7 | 3.407.1-143.8.30 | 8.4 |
| OG-13 | OG13, OG 13 | 3.407.1-143.8.36 | 7.3 |
| OG-14 | OG14, OG 14 | 3.407.1-143.8.37 | 7.6 |
| OG-15 | OG15, OG 15 | 3.407.1-143.8.38 | 14.7 |
OG and OT plates, OG-11 pin
Plates for the pole heads, plus auxiliary parts of the fixing assemblies.
| Designation | Also written | Drawing | Mass, kg |
|---|---|---|---|
| OG-2 | OG2, OG 2 | 3.407.1-143.8.27 | 1.6 |
| OG-5 | OG5, OG 5 | 3.407.1-143.8.28 | 1.1 |
| OG-6 | OG6, OG 6 | 3.407.1-143.8.29 | — |
| OG-8 | OG8, OG 8 | 3.407.1-143.8.31 | 3.1 |
| OG-9 | OG9, OG 9 | 3.407.1-143.8.32 | 2.5 |
| OG-10 | OG10, OG 10 | 3.407.1-143.8.33 | 4.5 |
| OG-11 | OG11, OG 11 | 3.407.1-143.8.34 | 0.7 |
| OG-12 | OG12, OG 12 | 3.407.1-143.8.35 | 4.3 |
| OT-6 | OT6, OT 6 | 3.407.1-143.8.48 | 5.0 |
B bolts and Kh clamps
Bolts and clamps fasten the parts to the shafts and to one another.
| Designation | Also written | Drawing | Mass, kg |
|---|---|---|---|
| B1 | B 1 | 3.407.1-143.8.39 | 0.7 |
| B5 | — | 3.407.1-143.8.39 | 0.6 |
| B6 | — | 3.407.1-143.8.39 | 1.2 |
| Kh33 | Kh 33 | 3.407.1-143.8.51 | 1.8 |
| Kh34 | Kh 34 | 3.407.1-143.8.51 | 2.0 |
| Kh35 | — | 3.407.1-143.8.51 | 2.6 |
| Kh36 | Kh 36 | 3.407.1-143.8.51 | 1.9 |
How to order the fittings
In the request, list the designations and quantities, for example: “TM-6 — 40 pcs, OG-13 — 40 pcs”. Say whether you need hot-dip galvanising. If a part differs from the standard one, attach a drawing.
The price depends on the quantity, coating and drawing, so we calculate it on request. The typical lead time is 3–4 weeks if the product is not in stock; we confirm the exact time after the calculation. The ordering procedure is described in the article How to order poles and masts, and the coating in more detail on the page Hot-dip galvanising. For an overview of the whole product group, see Structures for 0.4–10 kV overhead lines.
Updated:
Catalogue of fittings for 0.4–10 kV lines: frequently asked questions
What do TM, TS and OG stand for?
They are part codes from album 3.407.1-143: TM for cross-arms, TS for extensions, OG for pole heads and plates, OT for a plate, B for bolts, Kh for clamps. Each section heading names its group of parts.
Can I order parts that are not in the tables?
Yes. We make steel parts to your KM or KMD drawings. Send a drawing or a sketch and state the dimensions and quantity.
Do you galvanise the parts?
Yes, by hot-dip galvanising to DSTU EN ISO 1461:2024. The bath measures 13,000 × 1,600 × 3,200 mm, and there is no minimum order.
How much does a part cost, and when will it be ready?
The price depends on the quantity, coating and drawing, so we calculate it on request. The typical lead time is 3–4 weeks if the product is not in stock.
Related products: Overhead line fittings and crossarms (0.4-10 kV)
More on this topic: Cross-arms for 0.4–10 kV Lines: TM and TN Types, Reading the Designation
Get a quote for your requirements
Send us your requirements — we will calculate the price and lead time.